http://VACCUMPUMPMANUFACTURER.COM
DHVE 531da7cb4ec0a43f6814399a False 1858 22
OK
background image not found
Found Update results for
'gas'
5
Digital Penning Gauge - DHVE Thisis a cold cathode Ionisation gauge consisting of two electrodes anode and cathode. A potential difference of about 2.2 KV is applied between anode and cathode through current limiting resistors. A magnetic field is introduced at right angles to the plane of the electrodes by a permanent magnet having nearly 800 gauss magnetic field which will increase the ionisation current. The electrons emitted from the cathode (gauge head body) of the gauge head are deflected by means of magnetic field applied at right angles to the plane of the electrodes and are made to take helical path before reaching the anode loop. Thus following very long path, the chance of collision with gas molecule is high even at low pressures. The secondary electrons produced by ionisation themselves perform similar oscillations and the rate of ionisation increases rapidly. Eventually, the electrons are captured by the anode and equilibrium is reached when the number of electrons produced per second by ionisation is the sum of positive ion current to the cathode and the electron current to the anode and is used to measure the pressure of the gas. This instrument with the sensor having wider range of applications, in high vacuum systems where the final Vacuum to be measured in process chamber. These instruments can be used in high vacuum systems, coating units, sputtering units, vacuum furnaces and many other applications where high vacuum to be measured in the range of 10-2 to 10-6 m.bar.
ANALOG PIRANI VACUUM GAUGE DHVE pirani gauges have very wide range of applications where the vacuum measurement needs to be carried between 0.5 mbar to 0.001 mbar. Working principle: The sensor tube of the pirani gauge head consists of a high temperature co-efficient resistance filament. The filament is heated with a constant voltage supply. The variation in pressure in vacuum line causes changes concentration of gas molecules present , in turn the variation in the thermal conductivity of the gas. Hence the heat loss of the electrically heated filament varies with respect to the pressure. This filament is constructed as an arm of the wheat stone bridge. A slight change in system pressure brings larger change in filament resistivity resulting in an imbalance of the bridge. this bridge imbalance current is a measure of pressure which is properly conditioned and displayed on the analog meter.
• Vacuum Pump in delhi • Vacuum Measuring Instruments in delhi • Diffusion Pump in delhi • Gas Charging Unit in delhi • Vacuum Coating Plant in delhi • Tungsten Coil in delhi • Vacuum Oil in delhi
• Vacuum Pump in india • Vacuum Measuring Instruments in india • Diffusion Pump in india • Gas Charging Unit in india • Vacuum Coating Plant in india • Tungsten Coil in india • Vacuum Oil in india
Vacuum Pump manufacture • Vacuum Measuring Instruments manufacture • Diffusion Pump manufacture • Gas Charging Unit manufacture • Vacuum Coating Plant manufacture • Tungsten Coil manufacture • Vacuum oil manufacture DIGITAL PIRANI GAUGE MANUFACTURE SILICON OILMANUFACTURE VACUUM GEGES MANUFACTURE
1
false